Viaflex delivers outstanding customer service and high-quality, U.S.-made products – all with an eye on the horizon of earth industries.
Learn More
Use engineered geomembrane systems to support spill control, stormwater management and groundwater protection at renewable energy sites.
Renewable energy sites require more than equipment foundations and electrical infrastructure. Utility-scale solar projects and battery energy storage systems (BESS) must also manage transformer oil, dielectric fluids, battery coolant, stormwater, firewater and construction-phase runoff.
An engineered geomembrane liner can help isolate these fluids from soil and groundwater. Use the liner as part of a complete containment strategy that also includes drainage, collection, detection, treatment and mitigation systems.
Design the system around project-specific conditions. Evaluate the site, fluid exposures, structural loads, climate, slope geometry, installation method and requirements established by the project engineer and the authority having jurisdiction (AHJ).
Containment supports environmental protection and operational control in several ways:
Do not treat a liner as a substitute for required fire protection, leak detection, drainage, emergency response or regulatory controls. Battery chemistry, fire suppression design and code compliance remain governed by the project design, applicable codes and the AHJ.
Apply geomembrane systems where the site risk assessment identifies a credible pathway for fluids to reach soil or groundwater.
BESS secondary containment pads and berms
Place liners beneath or within engineered BESS containment areas where battery equipment, coolant systems or firewater could release liquids. Coordinate the liner with the structural pad, perimeter berms, collection sumps and access routes.
Protect the liner from equipment loads and construction traffic. Specify a concrete or other designed wearing surface when required. Do not allow forklifts, cranes, sharp aggregate or temporary supports to contact an unprotected geomembrane.
Transformer and substation oil containment
Use a geomembrane-lined berm, pit or pad to contain transformer oil. Direct drainage to a controlled collection point. Design discharge or treatment systems to prevent oil-contaminated water from leaving the containment area.
Verify compatibility with the actual transformer oil, coolant, additives and cleaning materials. Do not rely on a generic statement that a material is “chemical resistant” without a project-specific compatibility review.
Solar containment ponds and stormwater ponds
A solar farm pond liner may help reduce seepage in retention ponds, evaporation ponds and process water ponds. Define whether the pond will receive clean stormwater, sediment-laden construction runoff, process water or potentially contaminated water.
Separate clean stormwater infrastructure from BESS firewater and transformer containment. Do not route potentially contaminated flows to a clean stormwater pond without an approved treatment and management plan.
Construction-phase containment
Use temporary lined areas for equipment fueling, fluid storage, washdown, sediment control or staging when project conditions require additional protection. Establish removal, inspection and restoration requirements before installation.
Coordinate the liner with the equipment pad, berms, drainage structures and collection points.
Investigate the site first
Complete the geotechnical and environmental site investigation before selecting the liner system.
Document:
Prepare and protect the subgrade
Proof-roll, grade and compact the subgrade in accordance with the project specifications. Remove rocks, roots, debris, voids and abrupt grade changes that could puncture or overstress the liner.
Use geotextile cushioning or another approved protection layer where the subgrade or overlying materials could damage the geomembrane. Design protection layers above and below the liner based on expected loads and puncture risks.
Evaluate slopes and surface friction
Analyze slope stability for the entire interface system. Include the geomembrane, geotextile, drainage layer, cover soil, concrete or other overlying materials.
Select smooth or textured surfaces based on the design:
Account for exposure and weather
Define whether the liner will remain exposed or receive a cover. Evaluate:
Use anchor trenches, perimeter details, ballast or other engineered restraint as required. Do not leave deployed panels unsecured during wind events.
Detail penetrations and transitions
Treat every conduit, pipe, drain, sump, curb, foundation and structural penetration as a critical detail. Coordinate boots, collars, prefabricated fittings, weldable attachments and termination bars with the liner and adjacent structures.
Do not cut field penetrations without an approved detail. Do not bury untested transitions. Confirm that the penetration detail can accommodate movement, settlement and thermal changes.
Plan panel layout and welding
Develop the panel layout before fabrication and installation. Minimize unnecessary field seams while ensuring safe handling and proper fit around structures.
Use U.S. fabrication and custom panel sizes to support project logistics. Viaflex heat-fusion technology may help reduce field seaming when the product and project design are suitable.
Establish welding procedures, weather limits, trial seams, operator qualifications, seam identification and repair procedures. Complete non-destructive and destructive testing in accordance with the project specification.
Viaflex product families for project-specific evaluation include the HydraLine HD-Series (an HDPE geomembrane family), the HydraLine HDT-Series (an LLDPE geomembrane family), the HydraLine LL-Series (an LLDPE geomembrane family), the HydraLine LLT-Series (an LLDPE geomembrane family), the HydraFlex PRO HP-Series (a flexible LLDPE option for ponds and pits), the HydraFlex HT-Series (a one-side textured flexible LLDPE option and the XR-5 XR-Series (a reinforced ethylene interpolymer alloy geomembrane). Dura-Skrim N-Series may also be evaluated as a pond liner family.
Do not assume that any product is suitable for battery electrolyte, transformer oil, coolant, firewater or other fluids without reviewing the actual formulation, exposure duration, temperature and design conditions.
Require the project team to:
BESS containment is the engineered system that manages potential releases from battery energy storage equipment. It may include a geomembrane liner, structural pad, berms, drainage, collection, leak detection, firewater management and response procedures.
An HDPE liner may be suitable for certain BESS containment applications. Confirm suitability through a project-specific review of battery chemistry, coolant, firewater, temperature, loading, subgrade, protective layers, and installation requirements.
HDPE, LLDPE, flexible LLDPE and reinforced liner systems may be considered for solar farm ponds. Select the material based on water chemistry, slope geometry, settlement, UV exposure, puncture risk, anchoring and expected service conditions.
Design transformer oil containment separately from clean stormwater infrastructure unless the project engineer establishes an approved treatment and management system. Do not direct uncontrolled flow from oil containment to a clean pond.
No. A geomembrane liner is only one component of a complete containment strategy. Battery chemistry, fire suppression, detection, drainage, emergency response and code compliance remain project-specific responsibilities governed by the design team and the AHJ.
Viaflex offers U.S. fabrication and custom panel sizes. Heat-fusion technology may help reduce field seaming when product and project conditions support it. Coordinate fabrication requirements with the installation plan.
Installation and inspection services are available through Colorado Lining International, a Viaflex company. Services include certified installation, inspection and maintenance support, delivered by IAGI Certified Welding Technicians.
Select the geomembrane after defining the fluids, loads, slopes, climate, drainage strategy and inspection requirements. Use custom fabrication and qualified installation to control field seams and critical transitions. Coordinate the liner with the complete BESS or solar containment design rather than treating it as an isolated material purchase.
Review Viaflex geomembrane products and geomembrane applications, then submit project requirements through the Viaflex contact portal. Request a project-specific evaluation for renewable energy containment, including BESS containment, transformer oil containment and solar containment pond applications.